Novel materials for direct X-ray detectors based on semiconducting organic polymers

Carroli, Marco (2015) Novel materials for direct X-ray detectors based on semiconducting organic polymers. [Laurea magistrale], Università di Bologna, Corso di Studio in Fisica [LM-DM270]
Documenti full-text disponibili:
[thumbnail of carroli_marco_tesi.pdf]
Anteprima
Documento PDF
Download (10MB) | Anteprima

Abstract

Conventional inorganic materials for x-ray radiation sensors suffer from several drawbacks, including their inability to cover large curved areas, me- chanical sti ffness, lack of tissue-equivalence and toxicity. Semiconducting organic polymers represent an alternative and have been employed as di- rect photoconversion material in organic diodes. In contrast to inorganic detector materials, polymers allow low-cost and large area fabrication by sol- vent based methods. In addition their processing is compliant with fexible low-temperature substrates. Flexible and large-area detectors are needed for dosimetry in medical radiotherapy and security applications. The objective of my thesis is to achieve optimized organic polymer diodes for fexible, di- rect x-ray detectors. To this end polymer diodes based on two different semi- conducting polymers, polyvinylcarbazole (PVK) and poly(9,9-dioctyluorene) (PFO) have been fabricated. The diodes show state-of-the-art rectifying be- haviour and hole transport mobilities comparable to reference materials. In order to improve the X-ray stopping power, high-Z nanoparticle Bi2O3 or WO3 where added to realize a polymer-nanoparticle composite with opti- mized properities. X-ray detector characterization resulted in sensitivties of up to 14 uC/Gy/cm2 for PVK when diodes were operated in reverse. Addition of nanoparticles could further improve the performance and a maximum sensitivy of 19 uC/Gy/cm2 was obtained for the PFO diodes. Compared to the pure PFO diode this corresponds to a five-fold increase and thus highlights the potentiality of nanoparticles for polymer detector design. In- terestingly the pure polymer diodes showed an order of magnitude increase in sensitivity when operated in forward regime. The increase was attributed to a different detection mechanism based on the modulation of the diodes conductivity.

Abstract
Tipologia del documento
Tesi di laurea (Laurea magistrale)
Autore della tesi
Carroli, Marco
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Indirizzo
Curriculum C: Fisica della materia
Ordinamento Cds
DM270
Parole chiave
polymer detector nanoparticles
Data di discussione della Tesi
23 Ottobre 2015
URI

Altri metadati

Statistica sui download

Gestione del documento: Visualizza il documento

^