Analog and digital solutions for the implementation of a wearable device for the measurement of ECG and transthoracic impedance

Palanisamy, Dharani (2024) Analog and digital solutions for the implementation of a wearable device for the measurement of ECG and transthoracic impedance. [Laurea magistrale], Università di Bologna, Corso di Studio in Biomedical engineering [LM-DM270] - Cesena, Documento ad accesso riservato.
Documenti full-text disponibili:
[thumbnail of Thesis] Documento PDF (Thesis)
Full-text accessibile solo agli utenti istituzionali dell'Ateneo
Disponibile con Licenza: Salvo eventuali più ampie autorizzazioni dell'autore, la tesi può essere liberamente consultata e può essere effettuato il salvataggio e la stampa di una copia per fini strettamente personali di studio, di ricerca e di insegnamento, con espresso divieto di qualunque utilizzo direttamente o indirettamente commerciale. Ogni altro diritto sul materiale è riservato

Download (11MB) | Contatta l'autore

Abstract

Cardiovascular diseases account for 37% of all deaths in the European Union, and pulmonary diseases account for 8%. To reduce morbidity and mortality, it is crucial to identify markers of these diseases and monitor the health of the entire thoracic area, which houses the lungs and other vessels. The primary goals of this thesis are to conduct a thorough background investigation and identify the digital technologies, such as integrated circuits, microcontrollers, software algorithms, and analog solutions, required to create a wearable device for TTI and ECG monitoring. The aim is to prototype a portable, user-friendly, non-invasive method for monitoring cardiovascular health. The prototype integrates analog and digital components, including medical Analog Front Ends (AFEs), microcontrollers (MKW38), and communication protocols like SPI and Bluetooth. The software is developed using the MCUXpresso IDE provided by NXP Semiconductors. The prototype was evaluated using internal test signals and external human body signals. A series of experiments are conducted, including tests under various physiological conditions such as resting, forced breathing, and walking. The outcomes of this work include the successful acquisition of meaningful ECG and TTI signals. The relevance of these signals was confirmed across different physiological states, demonstrating the prototype's robustness in varied conditions. Furthermore, testing with standard external signals, such as square waves, produced outputs with low error, confirming the system's accuracy. These findings suggest that the prototype has the potential to be refined into a wearable device capable of precise ECG and TTI monitoring, allowing for early diagnosis and intervention in clinical and everyday settings. Future work includes further miniaturization and validation in clinical settings, and the inclusion of additional parameters.

Abstract
Tipologia del documento
Tesi di laurea (Laurea magistrale)
Autore della tesi
Palanisamy, Dharani
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Indirizzo
CURRICULUM INNOVATIVE TECHNOLOGIES IN DIAGNOSTICS AND THERAPY
Ordinamento Cds
DM270
Parole chiave
ECG,Transthoracic,Impedance,Analog,Front,Ends,ADS1298R,FRDM-KW38,Cardiac,Respiratory,Monitoring,Wearable,Devices.