Numerical study of the boil-off rate in a storage tank for liquid hydrogen

Viaro, Daniele (2022) Numerical study of the boil-off rate in a storage tank for liquid hydrogen. [Laurea magistrale], Università di Bologna, Corso di Studio in Ingegneria energetica [LM-DM270], Documento ad accesso riservato.
Documenti full-text disponibili:
[img] Documento PDF (Thesis)
Full-text accessibile solo agli utenti istituzionali dell'Ateneo
Disponibile con Licenza: Salvo eventuali più ampie autorizzazioni dell'autore, la tesi può essere liberamente consultata e può essere effettuato il salvataggio e la stampa di una copia per fini strettamente personali di studio, di ricerca e di insegnamento, con espresso divieto di qualunque utilizzo direttamente o indirettamente commerciale. Ogni altro diritto sul materiale è riservato

Download (14MB) | Contatta l'autore

Abstract

A widespread rollout of alternative fuels is desirable to mitigate the issue of global warming. Hydrogen is widely considered one of the most promising solutions to reduce the environmental impact of the transport sector. This thesis work, performed in collaboration with the Norwegian University of Science and Technology NTNU, is based on the numerical study of the boil-off rate (BOR) of liquid hydrogen. The BOF represents the amount of liquid hydrogen that evaporates and that must be vented, through a pressure relief valve, in order to avoid the overpressurization of the tank. The case study considered is a cryogenic tank with a maximum capacity of 900 kg used as storage system in a liquid hydrogen refueling station. Two different insulation systems were considered: the high-vacuum multilayer (MLI) and the polyurethane foam insulation. The numerical computation was performed with OpenFoam , a computational fluid dynamics (CFD) open-source software. In order to accurately simulate the evaporation process that takes place inside the tank the Lee evaporation model and the kinetic gas evaporation model were used and critically compared. The results obtained show a great difference in terms of BOR between these two insulation systems. A layer of 15 mm of MLI makes it possible to obtain a BOR value an order of magnitude lower than that obtained with 1 meter of polyurethane foam.

Abstract
Tipologia del documento
Tesi di laurea (Laurea magistrale)
Autore della tesi
Viaro, Daniele
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Ordinamento Cds
DM270
Parole chiave
liquid hydrogen,OpenFoam,hydrogen refueling station,CFD,cryogenic tank,Boil-off rate,venting
Data di discussione della Tesi
23 Marzo 2022
URI

Altri metadati

Statistica sui download

Gestione del documento: Visualizza il documento

^