Bosi, Marco
(2019)
Development of a distributed measurement system for detection of high impedance faults in medium voltage power lines.
[Laurea magistrale], Università di Bologna, Corso di Studio in
Ingegneria dell'energia elettrica [LM-DM270], Documento full-text non disponibile
Il full-text non è disponibile per scelta dell'autore.
(
Contatta l'autore)
Abstract
The aim of this thesis is to propose a new method to detect High impedance Faults, which relies on measuring the phase currents on electrical transmission and distribution grids using a common time source for synchronization. The goal is to measure the residual currents both at the transformer side and at the load side of the network. The time synchronization allows synchronized real-time measurements of the two residual currents at the two ends of the grid. In normal operating conditions and in all load conditions (balanced or unbalanced), the residual currents will result almost equal at the two ends. When a High Impedance Fault occurs, the residual currents at the two ends will differ. The difference in magnitude of the residual currents are monitored in real time and used as a pick-up criteria.
Abstract
The aim of this thesis is to propose a new method to detect High impedance Faults, which relies on measuring the phase currents on electrical transmission and distribution grids using a common time source for synchronization. The goal is to measure the residual currents both at the transformer side and at the load side of the network. The time synchronization allows synchronized real-time measurements of the two residual currents at the two ends of the grid. In normal operating conditions and in all load conditions (balanced or unbalanced), the residual currents will result almost equal at the two ends. When a High Impedance Fault occurs, the residual currents at the two ends will differ. The difference in magnitude of the residual currents are monitored in real time and used as a pick-up criteria.
Tipologia del documento
Tesi di laurea
(Laurea magistrale)
Autore della tesi
Bosi, Marco
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Indirizzo
Electrical Engineering
Ordinamento Cds
DM270
Parole chiave
High impendace faults,measurments,synchronization,current transformers,residual currents,real time data,electrical grid
Data di discussione della Tesi
19 Dicembre 2019
URI
Altri metadati
Tipologia del documento
Tesi di laurea
(NON SPECIFICATO)
Autore della tesi
Bosi, Marco
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Indirizzo
Electrical Engineering
Ordinamento Cds
DM270
Parole chiave
High impendace faults,measurments,synchronization,current transformers,residual currents,real time data,electrical grid
Data di discussione della Tesi
19 Dicembre 2019
URI
Gestione del documento: