Documenti full-text disponibili:
      
    
  
  
    
      Abstract
      In this study the main aim has been to analyse and improve some important aspects of the in-flight calibration process for the three Earth fly-bys planned for the ESA JUICE space mission.
In fact it has been developed a calibration script that is capable to correct uncalibrated data from the misallignment and scaling errors towards the expected values of magnetic field from IGRF13 model.
Also the experimental process of reproduction of the magnetic field data from JUICE Earth fly-bys prooved the efficiency of the script to control the instrumentation for the gain control during the in-flight calibration.
It has also been proved the low influece of the Soft Iron effect on the intrumentation, helping then to reduce the errors associated to misallignments and to the sensors offsets.
     
    
      Abstract
      In this study the main aim has been to analyse and improve some important aspects of the in-flight calibration process for the three Earth fly-bys planned for the ESA JUICE space mission.
In fact it has been developed a calibration script that is capable to correct uncalibrated data from the misallignment and scaling errors towards the expected values of magnetic field from IGRF13 model.
Also the experimental process of reproduction of the magnetic field data from JUICE Earth fly-bys prooved the efficiency of the script to control the instrumentation for the gain control during the in-flight calibration.
It has also been proved the low influece of the Soft Iron effect on the intrumentation, helping then to reduce the errors associated to misallignments and to the sensors offsets.
     
  
  
    
    
      Tipologia del documento
      Tesi di laurea
(Laurea magistrale)
      
      
      
      
        
      
        
          Autore della tesi
          Sanità, Lorenzo
          
        
      
        
          Relatore della tesi
          
          
        
      
        
          Correlatore della tesi
          
          
        
      
        
          Scuola
          
          
        
      
        
          Corso di studio
          
          
        
      
        
      
        
      
        
          Ordinamento Cds
          DM270
          
        
      
        
          Parole chiave
          In-flight calibration, magnetometer, space mission, JUICE
          
        
      
        
          Data di discussione della Tesi
          8 Ottobre 2020
          
        
      
      URI
      
      
     
   
  
    Altri metadati
    
      Tipologia del documento
      Tesi di laurea
(NON SPECIFICATO)
      
      
      
      
        
      
        
          Autore della tesi
          Sanità, Lorenzo
          
        
      
        
          Relatore della tesi
          
          
        
      
        
          Correlatore della tesi
          
          
        
      
        
          Scuola
          
          
        
      
        
          Corso di studio
          
          
        
      
        
      
        
      
        
          Ordinamento Cds
          DM270
          
        
      
        
          Parole chiave
          In-flight calibration, magnetometer, space mission, JUICE
          
        
      
        
          Data di discussione della Tesi
          8 Ottobre 2020
          
        
      
      URI
      
      
     
   
  
  
  
  
  
    
    Statistica sui download
    
    
  
  
    
      Gestione del documento: 
      
        