Study of the evolution of radiation-induced damage in silicon photomultipliers with emission microscopy

Rainero, Ludovica (2026) Study of the evolution of radiation-induced damage in silicon photomultipliers with emission microscopy. [Laurea magistrale], Università di Bologna, Corso di Studio in Physics [LM-DM270]
Documenti full-text disponibili:
[thumbnail of Thesis] Documento PDF (Thesis)
Disponibile con Licenza: Creative Commons: Attribuzione - Non commerciale - Non opere derivate 4.0 (CC BY-NC-ND 4.0)

Download (18MB)

Abstract

Silicon Photomultipliers (SiPMs) are promising photon sensors for the dual-radiator Ring Imaging Cherenkov detector of the ePIC experiment at the future Electron-Ion Collider, thanks to their single-photon sensitivity, fast response and insensitivity to magnetic fields. Their performance, however, is degraded by radiation damage, which increases dark-count rate and dark current. This thesis studies radiation-induced modifications and their evolution during thermal annealing using Emission Microscopy (EMMI), a spatially resolved technique sensitive to the secondary photons emitted during Geiger avalanches. Four Hamamatsu SiPMs with different microcell pitches were investigated after irradiation with approximately 140 MeV protons, corresponding to a neutron-equivalent fluence of 10^9 cm^-2; one device was also characterized before irradiation. The analysis includes hotspot counting, luminosity distributions, temperature and overvoltage dependences, population-averaged trends, and tracking of individual hotspots across successive annealing stages. Irradiation strongly increases the number of detectable hotspots: in the device measured both before and after irradiation, the count rises from 23±2 to 562±29, while all irradiated sensors show about 500–600 hotspots. At T=20°C and V_over=7 V, hotspot luminosities extend from about 25–480 a.u. before irradiation to values up to 1.2×10^4 a.u. after irradiation. During annealing, the whole-device hotspot population decreases by about 55–60%, while mean luminosity and dark current show even larger relative reductions. The hotspot luminosity increases approximately exponentially with temperature and approximately quadratically with overvoltage, although individual sites exhibit substantial variability. Overall, EMMI provides a sensitive spatial probe of radiation-induced avalanche activity and shows that annealing reduces both the number of detectable hotspots and the luminosity of the surviving population.

Abstract
Tipologia del documento
Tesi di laurea (Laurea magistrale)
Autore della tesi
Rainero, Ludovica
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Indirizzo
NUCLEAR AND SUBNUCLEAR PHYSICS
Ordinamento Cds
DM270
Parole chiave
SiPM,Radiation damage,Annealing,EIC,ePIC,dRICH,Emission Microscoy
Data di discussione della Tesi
29 Ottobre 2026
URI

Altri metadati

Statistica sui download

Gestione del documento: Visualizza il documento

^