Abstract
The object of this work is the implementation of an innovative offline adaptive radiotherapy software, ART.1, developed to overcome the inherent limitations of Cone Beam Computed Tomography (CBCT) imaging. To demonstrate its clinical validity, an experimental commissioning process was proposed in alignment with the protocol executed for standard CBCT, aiming to verify the clinical acceptability of contour propagation, dose
calculation, and synthetic CT (sCT) generation performed by ART.1. Specific comparisons between the standard radiotherapy Treatment Planning System (TPS) and the ART.1 workflow were executed to evaluate the sCT against the planning CT (pCT) using specific metrics (DSC and SSIM). To achieve this, specialized Python codes sourced from GitHub were first customized and then validated by running them on phantom images to ensure
metric calculation accuracy. To test both the responsiveness and robustness of ART.1, different clinical scenarios were investigated by simulating typical patient changes during RT treatment; anatomical variations (e.g., weight gain or loss) were simulated by adding tissue-equivalence bolus of varying thicknesses, and misalignments were replicated through manual shifts. Several tests were performed using different body mask thresholds
and slices per image. A statistical analysis of the obtained DSC and SSIM values has demonstrated a general validity of the sCT of ART.1 in correctly managing the presence of bolus, longitudinal shifts, and small rotations. Less satisfactory performances were ob
served when a lateral or a vertical shift was present. Here, the results showed values well below the theoretical minimum expected, demonstrating a failure of ART.1 to handle these types of misalignment.
Abstract
The object of this work is the implementation of an innovative offline adaptive radiotherapy software, ART.1, developed to overcome the inherent limitations of Cone Beam Computed Tomography (CBCT) imaging. To demonstrate its clinical validity, an experimental commissioning process was proposed in alignment with the protocol executed for standard CBCT, aiming to verify the clinical acceptability of contour propagation, dose
calculation, and synthetic CT (sCT) generation performed by ART.1. Specific comparisons between the standard radiotherapy Treatment Planning System (TPS) and the ART.1 workflow were executed to evaluate the sCT against the planning CT (pCT) using specific metrics (DSC and SSIM). To achieve this, specialized Python codes sourced from GitHub were first customized and then validated by running them on phantom images to ensure
metric calculation accuracy. To test both the responsiveness and robustness of ART.1, different clinical scenarios were investigated by simulating typical patient changes during RT treatment; anatomical variations (e.g., weight gain or loss) were simulated by adding tissue-equivalence bolus of varying thicknesses, and misalignments were replicated through manual shifts. Several tests were performed using different body mask thresholds
and slices per image. A statistical analysis of the obtained DSC and SSIM values has demonstrated a general validity of the sCT of ART.1 in correctly managing the presence of bolus, longitudinal shifts, and small rotations. Less satisfactory performances were ob
served when a lateral or a vertical shift was present. Here, the results showed values well below the theoretical minimum expected, demonstrating a failure of ART.1 to handle these types of misalignment.
Tipologia del documento
Tesi di laurea
(Laurea magistrale)
Autore della tesi
Galletta, Roberta
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Indirizzo
ADVANCED METHODS AND TECHNOLOGIES FOR ENERGY
Ordinamento Cds
DM270
Parole chiave
Head and neck cancer, Adaptive Radiotherapy (ART), Offline ART software, Synthetic CT (sCT), Commissioning, Image fidelity, Dose distribution, Phantom
Data di discussione della Tesi
7 Ottobre 2026
URI
Altri metadati
Tipologia del documento
Tesi di laurea
(NON SPECIFICATO)
Autore della tesi
Galletta, Roberta
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Indirizzo
ADVANCED METHODS AND TECHNOLOGIES FOR ENERGY
Ordinamento Cds
DM270
Parole chiave
Head and neck cancer, Adaptive Radiotherapy (ART), Offline ART software, Synthetic CT (sCT), Commissioning, Image fidelity, Dose distribution, Phantom
Data di discussione della Tesi
7 Ottobre 2026
URI
Statistica sui download
Gestione del documento: