Sviluppo di un metodo termoanalitico per la quantificazione di microplastiche in matrici complesse

Baldisserri, Giorgia (2022) Sviluppo di un metodo termoanalitico per la quantificazione di microplastiche in matrici complesse. [Laurea magistrale], Università di Bologna, Corso di Studio in Chimica industriale [LM-DM270], Documento ad accesso riservato.
Documenti full-text disponibili:
[img] Documento PDF (Thesis)
Full-text non accessibile fino al 7 Ottobre 2025.
Disponibile con Licenza: Creative Commons: Attribuzione - Non commerciale - Non opere derivate 4.0 (CC BY-NC-ND 4.0)

Download (2MB) | Contatta l'autore

Abstract

Microplastics (MPs) are highly debated emerging contaminants that are widespread on Earth. Nowadays, assessment of the risk that MPs pose on human health and environment were not developed yet, and standardized analytical methods for their quantification in complex matrices do not exist. Therefore, the formulation of standards which regulating MPs emission in the environment is not possible. The purpose of this study was to develop and apply a method for the analysis of MPs in sewage sludges and water from a wastewater treatment plant (WWTP), due to the relevance of those matrices as important pathway for MPs to enter the environment. Seven polymers were selected, because of their relevance on market production and their frequency of occurrence in such plants: polyethylene terephthalate (PET), polyethylene (PE), polypropylene (PP), polystyrene (PS), polycarbonate (PC), polyvinyl chloride (PVC), and nylon 6 (PA-6). In the study, a pre-treatment procedure was optimised using Fenton’s reagent and analyses carried out by combining thermochemolysis with Py-GC-MS after sample filtration on quartz (0.3 µm). Polymer quantification was performed with solid polymer mixture in silica and good correlations were obtained with internal calibration. As main results, Fenton's reagent negatively affected the recovery of some polymers (PP, PE, PS, PA-6) and a possible matrix interference was noticed, especially for PET and PVC. The WWTP allowed a good abatement of PS, PE, PP and PVC (on average 90 %) and comparable results were hypothesised for the other polymers. Polymer concentrations is sewage sludges ranged between < 2 μg/gdry and 3.5 mg/ gdry, for PC and PVC, respectively. Possible overestimations for PET and PVC, due to matrix interreferences, were taken into account and discussed.

Abstract
Tipologia del documento
Tesi di laurea (Laurea magistrale)
Autore della tesi
Baldisserri, Giorgia
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Indirizzo
CHIMICA INDUSTRIALE
Ordinamento Cds
DM270
Parole chiave
microplastiche Fenton impianti di depurazione pirolisi analitica
Data di discussione della Tesi
18 Ottobre 2022
URI

Altri metadati

Gestione del documento: Visualizza il documento

^