A single-sided NMR approach to study structural differences of bovine articular tissue

Golini, Carlo (2022) A single-sided NMR approach to study structural differences of bovine articular tissue. [Laurea magistrale], Università di Bologna, Corso di Studio in Physics [LM-DM270]
Documenti full-text disponibili:
[img] Documento PDF (Thesis)
Disponibile con Licenza: Creative Commons: Attribuzione - Non commerciale - Condividi allo stesso modo 4.0 (CC BY-NC-SA 4.0)

Download (24MB)

Abstract

This thesis work has been developed in collaboration between the Department of Physics and Astronomy of the University of Bologna and the IRCCS Rizzoli Orthopedic Institute during an internship period. The study aims to investigate the sensitivity of single-sided NMR in detecting structural differences of the articular cartilage tissue and their correlation with mechanical behavior. Suitable cartilage indicators for osteoarthritis (OA) severity (e.g., water and proteoglycans content, collagen structure) were explored through four NMR parameters: T2, T1, D, and Slp. Structural variations of the cartilage among its three layers (i.e., superficial, middle, and deep) were investigated performing several NMR pulses sequences on bovine knee joint samples using the NMR-MOUSE device. Previously, cartilage degradation studies were carried out, performing tests in three different experimental setups. The monitoring of the parameters and the best experimental setup were determined. An NMR automatized procedure based on the acquisition of these quantitative parameters was implemented, tested, and used for the investigation of the layers of twenty bovine cartilage samples. Statistical and pattern recognition analyses on these parameters have been performed. The results obtained from the analyses are very promising: the discrimination of the three cartilage layers shows very good results in terms of significance, paving the way for extensive use of NMR single-sided devices for biomedical applications. These results will be also integrated with analyses of tissue mechanical properties for a complete evaluation of cartilage changes throughout OA disease. The use of low-priced and mobile devices towards clinical applications could concern the screening of diseases related to cartilage tissue. This could have a positive impact both economically (including for underdeveloped countries) and socially, providing screening possibilities to a large part of the population.

Abstract
Tipologia del documento
Tesi di laurea (Laurea magistrale)
Autore della tesi
Golini, Carlo
Relatore della tesi
Correlatore della tesi
Scuola
Corso di studio
Indirizzo
Applied Physics
Ordinamento Cds
DM270
Parole chiave
Nuclear Magnetic Resonance,Relaxometry,Diffusometry,single-sided NMR,Cartilage,Porous Media
Data di discussione della Tesi
25 Marzo 2022
URI

Altri metadati

Statistica sui download

Gestione del documento: Visualizza il documento

^